Full-scale measurements and CFD reveal spatial zonation without internal partition walls at Meadville, Pennsylvania
Continuous inflow poses a fundamental question for sequencing batch reactors: how can incoming wastewater move through a basin that must also settle sludge and decant clarified water? At the Meadville Area Sewer Authority (MASA) in Pennsylvania, INVENT’s iSBR®-System combines cyclic treatment with a spatial cascade. Four process zones share one open basin. Their boundaries are created by the flow field rather than concrete walls.
A September 2025 field campaign, documented in a master’s thesis at Friedrich-Alexander-Universität Erlangen-Nürnberg, investigated how this arrangement behaves at full scale [1]. Simultaneous concentration measurements demonstrated spatially differentiated process behaviour. Computational fluid dynamics (CFD) provided a complementary picture of the circulation structures behind the virtual-wall concept.
Four zones, one continuous flow path
The iSBR® installation was commissioned in 2024. Meadville has a whole-plant design flow of 7.5 million US gallons per day, approximately 28,400 m³/d [5]. Four identical basins each measure 76.2 × 15.55 m, with an operating volume of approximately 5,593–7,406 m³. The installation comprises 16 HYPERCLASSIC®-Mixing and Aeration Systems and eight iDEC®-SBR Decanting Systems [1].
Each basin contains four zones, each served by one HYPERCLASSIC® mixer/aerator unit. Adjacent units rotate in opposite directions. Wastewater enters near the floor in Zone 1; two iDEC® decanting units withdraw clarified water near the surface in Zone 4. Mixing and aeration can be controlled independently. The cycle progresses through mixing, aeration, degassing, settling and decanting, with reduced mixing during settling and decanting. Inflow continues throughout.
Figure 1: The Meadville iSBR installation comprises four basins, each with four process zones and two decanters. Continuous inflow enters Zone 1; clarified water is withdrawn from Zone 4. Source: INVENT
Average plant flow during 11–29 September was 5,905 m³/d, approximately 21% of whole-plant design flow. The incoming flow was treated in two active basins initially and in one basin after the operating change described below.
What creates a virtual wall?
Hyperboloid mixing and aeration have a research history extending back to the 1990s [2,3]. At Meadville, the principle is applied to successive circulation cells along an elongated reactor. Where neighbouring flow structures meet, hydrodynamic separation zones form. These virtual walls permit exchange while maintaining spatial differentiation.
The CFD velocity fields show circulation cells in all four zones under both high-flow and low-flow conditions (Figure 2). Their similar structure suggests that mixer-induced circulation remains influential even when throughflow is low. The accompanying residence-time analysis describes a cascade with exchange between zones, rather than ideal plug flow or complete mixing throughout the basin. Its low-flow estimate is model-derived, not a full-scale tracer measurement [1].
Figure 2: CFD velocity magnitude and vectors in longitudinal reactor sections at 49,210 m³/d (reference case) and 5,905 m³/d (low-flow case). Circulation cells remain visible in all four zones. Source: Zeithammel (2026), Figure 4.12 [1]. Source: INVENT
The field evidence: different zones, different responses
Ion-selective sensors recorded ammonium and nitrate simultaneously in Zone 1 and Zone 4 from 14 to 16 September. Dissolved oxygen was also measured across all four zones. At 09:15 on 15 September, the plant changed from two active basins to one, directing the incoming load into half the previously active reactor volume.
Before the change, ammonium peaks in Zone 1 reached approximately 6-7 mg NH₄-N/L, while Zone 4 responded more slowly and with smaller fluctuations. After the switch, Zone 1 briefly approached 10 mg/L; the downstream response remained more gradual. The profiles sometimes converged, but their recurring differences show that the two locations did not behave as a single, completely mixed volume.
Nitrate showed the opposite spatial ordering. Before the switch, Zone 1 was commonly below 1 mg NO₃-N/L while Zone 4 reached around 3 mg/L. Afterwards, peaks were approximately 3 and 6 mg/L, respectively. Higher upstream ammonium and higher downstream nitrate are consistent with progressive nitrification along the cascade. Dissolved-oxygen profiles supplied further evidence of spatial differentiation [1].
Figure 3+4: Simultaneous NH₄-N (top) and NO₃-N (bottom) measurements in Zones 1 and 4, 14–16 September 2025. The dashed line marks the switch to single-basin operation. Different response dynamics and opposing concentration gradients demonstrate spatial zonation. Source: Zeithammel (2026), Figures 4.7 and 4.8 [1].
These are complementary, biologically coupled measurements. They establish operational zonation under the conditions studied; together with the CFD results, they support the interpretation of mixer-induced virtual walls. They do not, by themselves, isolate every contribution of mixing, transport and biological reaction. That distinction makes the evidence useful for engineering: the measured process response and the simulated flow mechanism can be assessed separately.
Effluent quality and an operational response
The campaign also captured a biological disturbance that the study linked to lipid loading following a malfunction in upstream grit and grease removal. Sludge settleability deteriorated, and nitrification was impaired. Measured decant-period ammonium means on 16–18 September ranged from 6.82 to 10.87 mg NH₄-N/L, above the process design target of 5 mg/L.
External 24-hour composite effluent samples nevertheless averaged 9.9 ± 4.1 mg/L total suspended solids and 6.1 ± 1.2 mg/L carbonaceous biochemical oxygen demand (cBOD₅), documenting the solids separation and biodegradable-carbon removal achieved during the monitoring period (means ± standard deviations). Following higher dissolved-oxygen setpoints and intensified aeration on 27 September, ammonium in effluent-proximal Zone 4 fell from 6–8 mg/L to approximately zero within 43 hours [1]. This records a successful operating response to the observed disturbance.
From a process concept to operating insight
The campaign also supported a dynamic SUMO model developed with Dynamita. It represented changing water levels, continuous feed, internal recycle, sludge wasting and decanting. The disturbance highlighted the limits of conventional biological kinetics when lipid-related oxygen-transfer effects become significant. The useful sequence is therefore to establish the reactor configuration and cycle logic, then calibrate biological behaviour against suitable operating data.
For utilities and designers, Meadville advances the cascaded, continuous and cyclic concept introduced in GWI in 2022 [4]. The measurements make spatial process differences visible; CFD connects them to a plausible hydrodynamic mechanism. Independently controllable mixing and aeration give operators practical means to respond. The result is a documented full-scale example of how flow design can organise treatment within an unpartitioned SBR.
Acknowledgement
The authors thank the Meadville Area Sewer Authority team for its practical support and open collaboration throughout the campaign. Particular thanks go to Howard Plant and Patty DeWalt for plant access, operational insight, laboratory support and assistance with the measurements.
Authors
Niklas Zeithammel, M.Sc., Ann-Kathrin Secknus, M.Eng., and Dr.-Ing. Marcus Höfken
References
[1] Zeithammel, N. (2026). Characterization and dynamic modeling of a continuously fed, cascaded SBR process. Master’s thesis, Friedrich-Alexander-Universität Erlangen-Nürnberg.
[2] Höfken, M., Zähringer, K. & Bischof, F. (1994). Stirring and aeration system for the upgrading of small waste water treatment plants. Water Science and Technology, 29(12), 149–156. https://doi.org/10.2166/wst.1994.0600
[3] Nouri, J. M. & Whitelaw, J. H. (1994). Flow characteristics of hyperboloid stirrers. The Canadian Journal of Chemical Engineering, 72(5), 782–791. https://doi.org/10.1002/cjce.5450720503
[4] INVENT (2022). iSBR®/iGSR®-Process: INVENT’s modern interpretation of the Sequencing Batch Reactor Process. GWI Partner Content.
[5] Pennsylvania Department of Environmental Protection (2025). Meadville Area Sewer Authority WWTP, PA0026271. Pennsylvania Bulletin, 55 Pa.B. 8766, 27 December. https://www.pacodeandbulletin.gov/secure/pabulletin/data/vol55/55-52/1764.html